Product Series
S 6512a F
Product description
- For fire protection doors with a steep turn-in curve
- Processing: butt joints
- Classification: EN 12365‑1 – W45243
- Operating force: EN 13115 – NPD
- Air permeability: EN 12207 – NPD
- Driving rain impermeability: EN 12208 – Class 9A
- Fire behaviour: EN 13501 – Class F
Advantages at a glance
- Good elastic recovery
- Convenient locking characteristics
- High tolerance intake
Variant / Color
Note: The colors shown are approximations and may differ from the original.
Signal black
similar to RAL 9004
SAP Number: 826172
SAP Number: 826172
Packing Unit
180 m Spool
Technical data
Position | Top,Left,Right,Frame |
Groove depth | 8 mm |
Groove width | 4 – 5 |
Raw material | TPE |
Rebate hight | 12 mm |
Stop distance | 5 mm |
Turn-in curve | Steep |